EN DE


                                         IT security technology
                                         IT Safety cells and Server Rooms

          T e c h n i c a l    i n f r a s t r u c t u r e   f o r   s e r v e r   r o o m s    a n d   d a t a   c e n t e r s   d i r e c t l y   f r o m   m a n u f a c t u r e r

INFRASTRUCTURE

Alarm Management

Fire Detection for cabinets

Fire Detection for rooms

Fire Prevention

Electrical wiring

Gas extinguishing systems
for cabinets

Gas extinguishing systems
for rooms

Fiber optic cable routing

Air conditioning for cabinets

Air conditioners for rooms

KVM Switches

LAN wiring

Emergency power systems
with diesel

Server Cabinets

Safes

UPS

Video Surveillance

Access Control


GREEN IT

Energy measurements

Solar power generators

Fuel Cells

Wind Generators

Free Cooling air systems


CONTACT

Head office:
BRODINGER

Bahnhofstrasse 9
4843 Ampflwang
Austria
Tel.:+43(0)7675 20121 Fax:+43(0)7675 20122

office@brodinger.at

Fire Detection for rooms


Branderkennung ohne Doppelboden   Branderkennung mit  Doppelboden

   Fire Detection for rooms

 

   Fire detection for rooms with the double bottom



Smoke detection systems for monitoring space with threshold alarm
stage for a
IT-security cell, or server room including installation.

Smoke detection systems are active systems.
Do not wait until the smoke rises, but suck at it.

Brandfrueherkennung-im-ServerrauSo that they respond much faster and more sensitive to emerging fires than traditional solutions. Our smoke detection system ideally combines the advantages of a regular reporting system with those of a point smoke detector.

Even the smallest amount of smoke it takes in active and evaluates them. This results in a variety of application possibilities for the protection of technical devices such as computer equipment or enclosures.

A smoke detection system consists essentially of two parts:
• branchable intake of any individual with small suction

• the detection chamber. This includes a smoke detector,
   a fan and the electronic    evaluation circuit.

The fan draws ambient air through the suction in the detection chamber, leading them to smoke. Smoke particles are registered there now.
With the limit value alarm is triggered.

FURTHER INFORMATION

Request to us

   Brochure BRODINGER

   Imageprospekt BRODINGER

NEWS

   ACTIONS-ACTIONS-ACTIONS
   Always on the cutting
   edge of technology


   Aktionen_Brodinger
   TRADE SHOWS

   ITnT2009








Copyright © 2010 Brodinger IT security technology ::: IT-safety cell and server rooms
Any reproduction of the stored data on the website on electromagnetic, electronic or other medium otto is prohibited.

Except for a single download or print out data from the running application for personal use only.