security cell as an area in space



ITSRFU100sm   IT_Sicherheitszelle 60min

ITSRFU100sm IT-Sicherheitszelle Datasheet

 

ITSRFU100 IT-Sicherheitszelle Video 24MB

An IT security cell provides comprehensive protection against:
Fire, fire water, fire, fumes, water damage, building moisture, dust, Debris loads, electromagnetic interference, theft, sabotage, overheating, system failure. Anhören Umschrift Wörterbuch - Detaillierten Wörterbucheintrag anzeigen
IT-security cell space in the room:
• have a full room in room construction, and protect against all the hardware therein occurring physical damage effects.

• are modular, fire resistance, smoke density, delete, waterproof, and debris loads geräuschedämmende scavenging security rooms.

• be installed individually depending on customer requirements in an existing building.
The footprint results from the necessary rack number.

• offer the opportunity with extensive accessories such as air conditioning, fire detection, extinguishing gas systems, UPS systems, access control and much more equipped to be.

• can be supplied to any size of 9m ².
The following international standards and certifications are available:
• General technical approval for all parts to DIN4102 F90/F120/F180.
• Temperature increase in the fire well within EN 1047 Part 2
• Water leakage rate 0 at vertical and oblique falling water
   as well as spray and splash.
• fire waterproof IP54.
• Smoke protection to DIN 18095-1.
• Protection from debris loads up to 300kg / m² with an IT cell DIN EN 14195th
• burglary after WW2 to WK6 DINENV1627: 1999.
• air permeability according to EN 12207 class 4
• Electrical ÖVE TAEV, EN 12646-1.

FURTHER INFORMATION

Request to us

   Brochure BRODINGER

   Imageprospekt BRODINGER

NEWS

Brodinger_Facebook   
SALE - ACTIONS -SALE
   Always on the cutting
   edge of technology


   Aktionen_Brodinger
   TRADE SHOWS

   ITnT2009











Copyright © 2010 Brodinger IT security technology ::: IT-safety cell and server rooms
Any reproduction of the stored data on the website on electromagnetic, electronic or other medium otto is prohibited.

Except for a single download or print out data from the running application for personal use only.